Class RpcMessage.Builder
java.lang.Object
com.google.protobuf.AbstractMessageLite.Builder
com.google.protobuf.AbstractMessage.Builder<BuilderT>
com.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
com.inductiveautomation.ignition.common.rpc.proto.gen.RpcMessage.Builder
- All Implemented Interfaces:
com.google.protobuf.Message.Builder,com.google.protobuf.MessageLite.Builder,com.google.protobuf.MessageLiteOrBuilder,com.google.protobuf.MessageOrBuilder,RpcMessageOrBuilder,Cloneable
- Enclosing class:
- RpcMessage
public static final class RpcMessage.Builder
extends com.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
implements RpcMessageOrBuilder
An RpcMessage is always either an actual value, or an error thrown on the gateway; nothing more and nothing less.Protobuf type
ignition.rpc.RpcMessage-
Method Summary
Modifier and TypeMethodDescriptionaddRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value) build()clear().ignition.rpc.Value actual = 1;.ignition.rpc.Error error = 3;clearField(com.google.protobuf.Descriptors.FieldDescriptor field) clearOneof(com.google.protobuf.Descriptors.OneofDescriptor oneof) clone().ignition.rpc.Value actual = 1;.ignition.rpc.Value actual = 1;.ignition.rpc.Value actual = 1;static final com.google.protobuf.Descriptors.Descriptorcom.google.protobuf.Descriptors.DescriptorgetError().ignition.rpc.Error error = 3;.ignition.rpc.Error error = 3;.ignition.rpc.Error error = 3;boolean.ignition.rpc.Value actual = 1;booleanhasError().ignition.rpc.Error error = 3;protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTablefinal booleanmergeActual(Value value) .ignition.rpc.Value actual = 1;mergeError(Error value) .ignition.rpc.Error error = 3;mergeFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) mergeFrom(com.google.protobuf.Message other) mergeFrom(RpcMessage other) final RpcMessage.BuildermergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) .ignition.rpc.Value actual = 1;setActual(Value.Builder builderForValue) .ignition.rpc.Value actual = 1;.ignition.rpc.Error error = 3;setError(Error.Builder builderForValue) .ignition.rpc.Error error = 3;setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, int index, Object value) final RpcMessage.BuildersetUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) Methods inherited from class com.google.protobuf.GeneratedMessageV3.Builder
getAllFields, getField, getFieldBuilder, getOneofFieldDescriptor, getParentForChildren, getRepeatedField, getRepeatedFieldBuilder, getRepeatedFieldCount, getUnknownFields, getUnknownFieldSetBuilder, hasField, hasOneof, internalGetMapField, internalGetMapFieldReflection, internalGetMutableMapField, internalGetMutableMapFieldReflection, isClean, markClean, mergeUnknownLengthDelimitedField, mergeUnknownVarintField, newBuilderForField, onBuilt, onChanged, parseUnknownField, setUnknownFieldSetBuilder, setUnknownFieldsProto3Methods inherited from class com.google.protobuf.AbstractMessage.Builder
findInitializationErrors, getInitializationErrorString, internalMergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, newUninitializedMessageException, toStringMethods inherited from class com.google.protobuf.AbstractMessageLite.Builder
addAll, addAll, mergeDelimitedFrom, mergeDelimitedFrom, mergeFrom, newUninitializedMessageExceptionMethods inherited from class java.lang.Object
equals, finalize, getClass, hashCode, notify, notifyAll, wait, wait, waitMethods inherited from interface com.google.protobuf.Message.Builder
mergeDelimitedFrom, mergeDelimitedFromMethods inherited from interface com.google.protobuf.MessageLite.Builder
mergeFromMethods inherited from interface com.google.protobuf.MessageOrBuilder
findInitializationErrors, getAllFields, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof
-
Method Details
-
getDescriptor
public static final com.google.protobuf.Descriptors.Descriptor getDescriptor() -
internalGetFieldAccessorTable
protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()- Specified by:
internalGetFieldAccessorTablein classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
clear
- Specified by:
clearin interfacecom.google.protobuf.Message.Builder- Specified by:
clearin interfacecom.google.protobuf.MessageLite.Builder- Overrides:
clearin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
getDescriptorForType
public com.google.protobuf.Descriptors.Descriptor getDescriptorForType()- Specified by:
getDescriptorForTypein interfacecom.google.protobuf.Message.Builder- Specified by:
getDescriptorForTypein interfacecom.google.protobuf.MessageOrBuilder- Overrides:
getDescriptorForTypein classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
getDefaultInstanceForType
- Specified by:
getDefaultInstanceForTypein interfacecom.google.protobuf.MessageLiteOrBuilder- Specified by:
getDefaultInstanceForTypein interfacecom.google.protobuf.MessageOrBuilder
-
build
- Specified by:
buildin interfacecom.google.protobuf.Message.Builder- Specified by:
buildin interfacecom.google.protobuf.MessageLite.Builder
-
buildPartial
- Specified by:
buildPartialin interfacecom.google.protobuf.Message.Builder- Specified by:
buildPartialin interfacecom.google.protobuf.MessageLite.Builder
-
clone
- Specified by:
clonein interfacecom.google.protobuf.Message.Builder- Specified by:
clonein interfacecom.google.protobuf.MessageLite.Builder- Overrides:
clonein classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
setField
public RpcMessage.Builder setField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value) - Specified by:
setFieldin interfacecom.google.protobuf.Message.Builder- Overrides:
setFieldin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
clearField
- Specified by:
clearFieldin interfacecom.google.protobuf.Message.Builder- Overrides:
clearFieldin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
clearOneof
- Specified by:
clearOneofin interfacecom.google.protobuf.Message.Builder- Overrides:
clearOneofin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
setRepeatedField
public RpcMessage.Builder setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, int index, Object value) - Specified by:
setRepeatedFieldin interfacecom.google.protobuf.Message.Builder- Overrides:
setRepeatedFieldin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
addRepeatedField
public RpcMessage.Builder addRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value) - Specified by:
addRepeatedFieldin interfacecom.google.protobuf.Message.Builder- Overrides:
addRepeatedFieldin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
mergeFrom
- Specified by:
mergeFromin interfacecom.google.protobuf.Message.Builder- Overrides:
mergeFromin classcom.google.protobuf.AbstractMessage.Builder<RpcMessage.Builder>
-
mergeFrom
-
isInitialized
public final boolean isInitialized()- Specified by:
isInitializedin interfacecom.google.protobuf.MessageLiteOrBuilder- Overrides:
isInitializedin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
mergeFrom
public RpcMessage.Builder mergeFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException - Specified by:
mergeFromin interfacecom.google.protobuf.Message.Builder- Specified by:
mergeFromin interfacecom.google.protobuf.MessageLite.Builder- Overrides:
mergeFromin classcom.google.protobuf.AbstractMessage.Builder<RpcMessage.Builder>- Throws:
IOException
-
getValueCase
- Specified by:
getValueCasein interfaceRpcMessageOrBuilder
-
clearValue
-
hasActual
public boolean hasActual().ignition.rpc.Value actual = 1;- Specified by:
hasActualin interfaceRpcMessageOrBuilder- Returns:
- Whether the actual field is set.
-
getActual
.ignition.rpc.Value actual = 1;- Specified by:
getActualin interfaceRpcMessageOrBuilder- Returns:
- The actual.
-
setActual
.ignition.rpc.Value actual = 1; -
setActual
.ignition.rpc.Value actual = 1; -
mergeActual
.ignition.rpc.Value actual = 1; -
clearActual
.ignition.rpc.Value actual = 1; -
getActualBuilder
.ignition.rpc.Value actual = 1; -
getActualOrBuilder
.ignition.rpc.Value actual = 1;- Specified by:
getActualOrBuilderin interfaceRpcMessageOrBuilder
-
hasError
public boolean hasError().ignition.rpc.Error error = 3;- Specified by:
hasErrorin interfaceRpcMessageOrBuilder- Returns:
- Whether the error field is set.
-
getError
.ignition.rpc.Error error = 3;- Specified by:
getErrorin interfaceRpcMessageOrBuilder- Returns:
- The error.
-
setError
.ignition.rpc.Error error = 3; -
setError
.ignition.rpc.Error error = 3; -
mergeError
.ignition.rpc.Error error = 3; -
clearError
.ignition.rpc.Error error = 3; -
getErrorBuilder
.ignition.rpc.Error error = 3; -
getErrorOrBuilder
.ignition.rpc.Error error = 3;- Specified by:
getErrorOrBuilderin interfaceRpcMessageOrBuilder
-
setUnknownFields
- Specified by:
setUnknownFieldsin interfacecom.google.protobuf.Message.Builder- Overrides:
setUnknownFieldsin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-
mergeUnknownFields
public final RpcMessage.Builder mergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) - Specified by:
mergeUnknownFieldsin interfacecom.google.protobuf.Message.Builder- Overrides:
mergeUnknownFieldsin classcom.google.protobuf.GeneratedMessageV3.Builder<RpcMessage.Builder>
-