Class ScriptingPb.Dataset.Column

java.lang.Object
com.google.protobuf.AbstractMessageLite
com.google.protobuf.AbstractMessage
com.google.protobuf.GeneratedMessageV3
com.inductiveautomation.ignition.common.script.proto.gen.ScriptingPb.Dataset.Column
All Implemented Interfaces:
com.google.protobuf.Message, com.google.protobuf.MessageLite, com.google.protobuf.MessageLiteOrBuilder, com.google.protobuf.MessageOrBuilder, ScriptingPb.Dataset.ColumnOrBuilder, Serializable
Enclosing class:
ScriptingPb.Dataset

public static final class ScriptingPb.Dataset.Column extends com.google.protobuf.GeneratedMessageV3 implements ScriptingPb.Dataset.ColumnOrBuilder
Protobuf type ignition.script.Dataset.Column
See Also:
  • Field Details

  • Method Details

    • newInstance

      protected Object newInstance(com.google.protobuf.GeneratedMessageV3.UnusedPrivateParameter unused)
      Overrides:
      newInstance in class com.google.protobuf.GeneratedMessageV3
    • getDescriptor

      public static final com.google.protobuf.Descriptors.Descriptor getDescriptor()
    • internalGetFieldAccessorTable

      protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
      Specified by:
      internalGetFieldAccessorTable in class com.google.protobuf.GeneratedMessageV3
    • getName

      public String getName()
      string name = 1;
      Specified by:
      getName in interface ScriptingPb.Dataset.ColumnOrBuilder
      Returns:
      The name.
    • getNameBytes

      public com.google.protobuf.ByteString getNameBytes()
      string name = 1;
      Specified by:
      getNameBytes in interface ScriptingPb.Dataset.ColumnOrBuilder
      Returns:
      The bytes for name.
    • getType

      public String getType()
      string type = 2;
      Specified by:
      getType in interface ScriptingPb.Dataset.ColumnOrBuilder
      Returns:
      The type.
    • getTypeBytes

      public com.google.protobuf.ByteString getTypeBytes()
      string type = 2;
      Specified by:
      getTypeBytes in interface ScriptingPb.Dataset.ColumnOrBuilder
      Returns:
      The bytes for type.
    • getValueList

      public List<Value> getValueList()
      repeated .ignition.rpc.Value value = 3;
      Specified by:
      getValueList in interface ScriptingPb.Dataset.ColumnOrBuilder
    • getValueOrBuilderList

      public List<? extends ValueOrBuilder> getValueOrBuilderList()
      repeated .ignition.rpc.Value value = 3;
      Specified by:
      getValueOrBuilderList in interface ScriptingPb.Dataset.ColumnOrBuilder
    • getValueCount

      public int getValueCount()
      repeated .ignition.rpc.Value value = 3;
      Specified by:
      getValueCount in interface ScriptingPb.Dataset.ColumnOrBuilder
    • getValue

      public Value getValue(int index)
      repeated .ignition.rpc.Value value = 3;
      Specified by:
      getValue in interface ScriptingPb.Dataset.ColumnOrBuilder
    • getValueOrBuilder

      public ValueOrBuilder getValueOrBuilder(int index)
      repeated .ignition.rpc.Value value = 3;
      Specified by:
      getValueOrBuilder in interface ScriptingPb.Dataset.ColumnOrBuilder
    • getQualityList

      public List<Integer> getQualityList()
      repeated int32 quality = 4;
      Specified by:
      getQualityList in interface ScriptingPb.Dataset.ColumnOrBuilder
      Returns:
      A list containing the quality.
    • getQualityCount

      public int getQualityCount()
      repeated int32 quality = 4;
      Specified by:
      getQualityCount in interface ScriptingPb.Dataset.ColumnOrBuilder
      Returns:
      The count of quality.
    • getQuality

      public int getQuality(int index)
      repeated int32 quality = 4;
      Specified by:
      getQuality in interface ScriptingPb.Dataset.ColumnOrBuilder
      Parameters:
      index - The index of the element to return.
      Returns:
      The quality at the given index.
    • isInitialized

      public final boolean isInitialized()
      Specified by:
      isInitialized in interface com.google.protobuf.MessageLiteOrBuilder
      Overrides:
      isInitialized in class com.google.protobuf.GeneratedMessageV3
    • writeTo

      public void writeTo(com.google.protobuf.CodedOutputStream output) throws IOException
      Specified by:
      writeTo in interface com.google.protobuf.MessageLite
      Overrides:
      writeTo in class com.google.protobuf.GeneratedMessageV3
      Throws:
      IOException
    • getSerializedSize

      public int getSerializedSize()
      Specified by:
      getSerializedSize in interface com.google.protobuf.MessageLite
      Overrides:
      getSerializedSize in class com.google.protobuf.GeneratedMessageV3
    • equals

      public boolean equals(Object obj)
      Specified by:
      equals in interface com.google.protobuf.Message
      Overrides:
      equals in class com.google.protobuf.AbstractMessage
    • hashCode

      public int hashCode()
      Specified by:
      hashCode in interface com.google.protobuf.Message
      Overrides:
      hashCode in class com.google.protobuf.AbstractMessage
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(ByteBuffer data) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(ByteBuffer data, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(com.google.protobuf.ByteString data) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(com.google.protobuf.ByteString data, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(byte[] data) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(byte[] data, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(InputStream input) throws IOException
      Throws:
      IOException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(InputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Throws:
      IOException
    • parseDelimitedFrom

      public static ScriptingPb.Dataset.Column parseDelimitedFrom(InputStream input) throws IOException
      Throws:
      IOException
    • parseDelimitedFrom

      public static ScriptingPb.Dataset.Column parseDelimitedFrom(InputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Throws:
      IOException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(com.google.protobuf.CodedInputStream input) throws IOException
      Throws:
      IOException
    • parseFrom

      public static ScriptingPb.Dataset.Column parseFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Throws:
      IOException
    • newBuilderForType

      public ScriptingPb.Dataset.Column.Builder newBuilderForType()
      Specified by:
      newBuilderForType in interface com.google.protobuf.Message
      Specified by:
      newBuilderForType in interface com.google.protobuf.MessageLite
    • newBuilder

      public static ScriptingPb.Dataset.Column.Builder newBuilder()
    • newBuilder

      public static ScriptingPb.Dataset.Column.Builder newBuilder(ScriptingPb.Dataset.Column prototype)
    • toBuilder

      Specified by:
      toBuilder in interface com.google.protobuf.Message
      Specified by:
      toBuilder in interface com.google.protobuf.MessageLite
    • newBuilderForType

      protected ScriptingPb.Dataset.Column.Builder newBuilderForType(com.google.protobuf.GeneratedMessageV3.BuilderParent parent)
      Specified by:
      newBuilderForType in class com.google.protobuf.GeneratedMessageV3
    • getDefaultInstance

      public static ScriptingPb.Dataset.Column getDefaultInstance()
    • parser

      public static com.google.protobuf.Parser<ScriptingPb.Dataset.Column> parser()
    • getParserForType

      public com.google.protobuf.Parser<ScriptingPb.Dataset.Column> getParserForType()
      Specified by:
      getParserForType in interface com.google.protobuf.Message
      Specified by:
      getParserForType in interface com.google.protobuf.MessageLite
      Overrides:
      getParserForType in class com.google.protobuf.GeneratedMessageV3
    • getDefaultInstanceForType

      public ScriptingPb.Dataset.Column getDefaultInstanceForType()
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.MessageLiteOrBuilder
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.MessageOrBuilder